Bug #48828 Conflict when selecting restart type
Submitted: 17 Nov 2009 7:31 Modified: 23 Dec 2009 14:19
Reporter: Daniel Herlitz Email Updates:
Status: No Feedback Impact on me:
None 
Category:MySQL Cluster: Cluster (NDB) storage engine Severity:S2 (Serious)
Version:6.3.20 OS:Linux
Assigned to: Assigned Account CPU Architecture:Any

[17 Nov 2009 7:31] Daniel Herlitz
Description:
After routine maintenance tonight, NDB decided not to start up again:

ndb_mgm> Node 2: Forced node shutdown completed. Occured during startphase 4. Caused by error 2311: 'Conflict when selecting restart type(Internal error, programming error or missing error message, please report a bug). Temporary error, restart node'.

sNode 3: Forced node shutdown completed. Occured during startphase 4. Caused by error 2308: 'Another node failed during system restart, please investigate error(s) on other node(s)(Restart error). Temporary error, restart node'.

How to repeat:
Don't know

Suggested fix:
Don't know
[17 Nov 2009 7:31] Daniel Herlitz
Error report

Attachment: ndb_error_report_20091117083025.tar.bz2 (application/octet-stream, text), 225.79 KiB.

[23 Nov 2009 14:19] Martin Skold
Please provide information on what type of maintenance operations were performed.
[24 Dec 2009 0:00] Bugs System
No feedback was provided for this bug for over a month, so it is
being suspended automatically. If you are able to provide the
information that was originally requested, please do so and change
the status of the bug back to "Open".