Bug #19844 | time_format in Union truncates values | ||
---|---|---|---|
Submitted: | 16 May 2006 10:17 | Modified: | 12 Sep 2006 1:42 |
Reporter: | Armin Lorenz | Email Updates: | |
Status: | Closed | Impact on me: | |
Category: | MySQL Server | Severity: | S2 (Serious) |
Version: | 4.1.15, 5.0bk | OS: | Windows (W2K) |
Assigned to: | Tatiana Azundris Nuernberg | CPU Architecture: | Any |
[16 May 2006 10:17]
Armin Lorenz
[16 May 2006 11:17]
Hartmut Holzgraefe
Veriefied on latest 4.1 and 5.0 sources using Linux
[16 May 2006 11:23]
Hartmut Holzgraefe
mysqltest test case
Attachment: bug19844.tar.gz (application/x-gzip, text), 521 bytes.
[7 Aug 2006 11:02]
Bugs System
A patch for this bug has been committed. After review, it may be pushed to the relevant source trees for release in the next version. You can access the patch from: http://lists.mysql.com/commits/10111 ChangeSet@1.2537, 2006-08-07 13:02:28+02:00, tnurnberg@salvation.intern.azundris.com +3 -0 Bug#19844: time_format in Union truncates values time_format() claimed %H and %k would return at most two digits (hours 0-23), but this coincided neither with actual behaviour nor with docs. this is not visible in simple queries; forcing a temp-table is probably the easiest way to see this. adjusted the return-length appropriately; the alternative would be to adjust the docs to say that behaviour for > 99 hours is undefined.
[10 Aug 2006 13:37]
Bugs System
A patch for this bug has been committed. After review, it may be pushed to the relevant source trees for release in the next version. You can access the patch from: http://lists.mysql.com/commits/10266 ChangeSet@1.2537, 2006-08-10 15:37:24+02:00, tnurnberg@salvation.intern.azundris.com +3 -0 Bug#19844: time_format in Union truncates values time_format() claimed %H and %k would return at most two digits (hours 0-23), but this coincided neither with actual behaviour nor with docs. this is not visible in simple queries; forcing a temp-table is probably the easiest way to see this. adjusted the return-length appropriately; the alternative would be to adjust the docs to say that behaviour for > 99 hours is undefined. --- Bug#19844: time_format in Union truncates values time_format() claimed %H and %k would return at most two digits (hours 0-23), but this coincided neither with actual behaviour nor with docs. this is not visible in simple queries; forcing a temp-table is probably the easiest way to see this. adjusted the return-length appropriately; the alternative would be to adjust the docs to say that behaviour for > 99 hours is undefined.
[11 Aug 2006 1:43]
Tatiana Azundris Nuernberg
pushed to 4.1-maint for 4.1.22
[17 Aug 2006 2:46]
Iggy Galarza
Available in 5.0.25
[12 Sep 2006 1:42]
Paul DuBois
Noted in 4.1.22, 5.0.25 changelogs. For TIME_FORMAT(), the %H and %k format specifiers can return values larger than two digits (if the hour is greater than 99), but for some query results that contained three-character hours, column values were truncated.